magent

Deterministic published-formula arithmetic plus ICD-10-CM, RxNorm, and LOINC. Pay in USDC on Base via x402.

SearchLiveeip155:8453Exactvia cdp
VexusVexus-cCongestionHemodynamicsCalculator
Calls · 30d
3→ 0%
This endpoint's own trailing-30-day call count, as published by the upstream catalog and snapshotted daily. 10 snapshots so far.
$13.75
Verified settled volume
2,750 settlements proven x402 by their on-chain EIP-3009 marker.
$0.0050
Listed price
As published in the catalog. Always read the live 402 before paying.
3
Calls · 30d
Upstream's own call count for this endpoint, not ours.
1
Unique payers · 30d
Last called 2026-08-31 12:55Z
—
Upstream on-chain volume
Reported by the source catalog.
Paid to
0x836Be278f1739fB4308091cD1852F7971Bc19Ee2

The wallet the 402 directs payment to. Its whole payment record — every payer, every chain — is on the merchant page.

Asset 0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913

Provider

The payTo wallet does not resolve to a registered ERC-8004 agent. That is not a verdict on the service — most of the catalog is unregistered.

Live 402 challenge

Captured by the enrichment pass, not read just now. Prices can change — always read the 402 the endpoint answers with.

{
  "error": "PAYMENT-SIGNATURE header is required",
  "accepts": [
    {
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "extra": {
        "name": "USD Coin",
        "version": "2",
        "paymentFlow": "upfront",
        "resourceUrl": "https://api.magentlab.com/api/calc/vexus",
        "assetTransferMethod": "eip3009"
      },
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "amount": "5000",
      "scheme": "exact",
      "network": "eip155:8453",
      "maxTimeoutSeconds": 600
    },
    {
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "extra": {
        "name": "USD Coin",
        "version": "2",
        "withdrawDelay": 86400,
        "receiverAuthorizer": "0x3721824a31197dcDD2984cF43b92B6cc8A87c0Fb",
        "assetTransferMethod": "eip3009"
      },
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "amount": "5000",
      "scheme": "batch-settlement",
      "network": "eip155:8453",
      "maxTimeoutSeconds": 600
    }
  ],
  "resource": {
    "url": "https://api.magentlab.com/api/calc/vexus",
    "tags": [
      "vexus",
      "vexus-c",
      "congestion",
      "hemodynamics",
      "calculator"
    ],
    "mimeType": "application/json",
    "description": "Beaubien-Souligny 2020 VExUS C only (not A, B, D, or E). Caller-assigned ivc_dilated (IVC ≥2 cm) plus hepatic, portal, and intra-renal Doppler each normal, mild, or severe. Grade 0 if the IVC is not dilated; 1 if dilated with zero severe patterns; 2 if exactly one severe; 3 if two or more are severe. magent does not perform ultrasound. Not an AKI diagnosis or a fluid-order. Not a medical device.",
    "serviceName": "magent"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "input": {
          "type": "http",
          "method": "GET",
          "queryParams": {
            "renal": "normal",
            "portal": "normal",
            "hepatic": "normal",
            "ivc_dilated": false
          }
        },
        "output": {
          "type": "json",
          "example": {
            "renal": "normal",
            "portal": "normal",
            "formula": "vexus",
            "hepatic": "normal",
            "citation": {
              "id": "beaubien-souligny-2020",
              "doi": "10.1186/s13089-020-00163-w",
              "pmid": "32270297",
              "title": "Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system",
              "source": "Ultrasound J. 2020;12(1):16",
              "authors": "Beaubien-Souligny W, Rola P, Haycock K, Bouchard J, Lamarche Y, Spiegel R, Denault AY"
            },
            "components": [
              {
                "met": false,
                "factor": "ivc_dilated"
              },
              {
                "met": false,
                "value": "normal",
                "factor": "hepatic_severe"
              },
              {
                "met": false,
                "value": "normal",
                "factor": "portal_severe"
              },
              {
                "met": false,
                "value": "normal",
                "factor": "renal_severe"
              },
              {
                "met": true,
                "factor": "grade_0"
              },
              {
                "met": false,
                "factor": "grade_1"
              },
              {
                "met": false,
                "factor": "grade_2"
              },
              {
                "met": false,
                "factor": "grade_3"
              }
            ],
            "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
            "ivc_dilated": false,
            "vexus_grade": 0,
            "formula_expression": "VExUS C grade 0 if ivc_dilated is false (regardless of Doppler); else 1 if zero of hepatic/portal/renal are severe; 2 if exactly one is severe; 3 if two or more are severe (Beaubien-Souligny 2020 prototype C). Hepatic: normal (triphasic S>D toward liver), mild (S<D toward liver), severe (S reversed toward heart). Portal: mild pulsatility 30 to <50%, severe ≥50%. Renal: mild discontinuous S and D, severe only D. IVC dilated iff maximal diameter ≥2 cm as assigned. Not prototypes A, B, D, E",
            "severe_doppler_count": 0
          }
        },
        "iconUrl": "https://api.magentlab.com/favicon.ico"
      },
      "schema": {
        "type": "object",
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "required": [
          "input"
        ],
        "properties": {
          "input": {
            "type": "object",
            "required": [
              "type",
              "method"
            ],
            "properties": {
              "type": {
                "type": "string",
                "const": "http"
              },
              "method": {
                "enum": [
                  "GET",
                  "HEAD",
                  "DELETE"
                ],
                "type": "string"
              },
              "headers": {
                "type": "object",
                "additionalProperties": {
                  "type": "string"
                }
              },
              "queryParams": {
                "type": "object",
                "required": [
                  "ivc_dilated",
                  "hepatic",
                  "portal",
                  "renal"
                ],
                "properties": {
                  "renal": {
                    "enum": [
                      "normal",
                      "mild",
                      "severe"
                    ],
                    "type": "string",
                    "description": "Intra-renal venous Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1): normal (continuous flow); mild (discontinuous with a systolic and a diastolic phase); severe (discontinuous with only a diastolic phase during the cardiac cycle). magent does not perform ultrasound."
                  },
                  "portal": {
                    "enum": [
                      "normal",
                      "mild",
                      "severe"
                    ],
                    "type": "string",
                    "description": "Portal-vein Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1 caption): normal (pulsatility fraction not in the mild or severe bands); mild (velocity variation 30 to <50%); severe (variation ≥50%). magent does not perform ultrasound."
                  },
                  "hepatic": {
                    "enum": [
                      "normal",
                      "mild",
                      "severe"
                    ],
                    "type": "string",
                    "description": "Hepatic-vein Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1): normal (not mild and not severe; triphasic S > D toward the liver); mild (S component lower in magnitude than D but still toward the liver); severe (S component reversed, toward the heart). magent does not perform ultrasound."
                  },
                  "ivc_dilated": {
                    "type": "boolean",
                    "description": "Whether the IVC is dilated as assigned by the caller. Dilated iff maximal IVC diameter ≥2 cm (Beaubien-Souligny 2020). true or false. Grade 0 whenever this is false, regardless of Doppler. magent does not measure IVC."
                  }
                }
              }
            },
            "additionalProperties": false
          },
          "output": {
            "type": "object",
            "required": [
              "type"
            ],
            "properties": {
              "type": {
                "type": "string"
              },
              "example": {
                "type": "object"
              }
            }
          }
        }
      }
    }
  },
  "x402Version": 2
}

Accepts

The payment requirements as published to the catalog. Read the live 402 before paying — a price here is a claim, not a quote.

0.005USDC≈ $0.005 USD
on Base · exact scheme

Pay 0.005 USDC on Base to 0x836B…19Ee2. The signed payment is good for 10 minutes.

USD Coin contract
0x8335…02913
Payment window
10 minutes
As published
5000 smallest units
The catalog’s raw entry
[
  {
    "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
    "extra": {
      "name": "USD Coin",
      "version": "2",
      "paymentFlow": "upfront",
      "resourceUrl": "https://api.magentlab.com/api/calc/vexus",
      "assetTransferMethod": "eip3009"
    },
    "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
    "amount": "5000",
    "scheme": "exact",
    "network": "eip155:8453",
    "maxTimeoutSeconds": 600
  }
]

Extensions

{
  "bazaar": {
    "info": {
      "input": {
        "body": {
          "items": [
            {
              "renal": "normal",
              "portal": "normal",
              "hepatic": "normal",
              "ivc_dilated": false
            },
            {
              "renal": "normal",
              "portal": "normal",
              "hepatic": "normal",
              "ivc_dilated": false
            }
          ]
        },
        "type": "http",
        "method": "POST"
      },
      "output": {
        "type": "json",
        "example": {
          "path": "/api/calc/vexus",
          "count": 2,
          "items": [
            {
              "renal": "normal",
              "portal": "normal",
              "formula": "vexus",
              "hepatic": "normal",
              "citation": {
                "id": "beaubien-souligny-2020",
                "doi": "10.1186/s13089-020-00163-w",
                "pmid": "32270297",
                "title": "Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system",
                "source": "Ultrasound J. 2020;12(1):16",
                "authors": "Beaubien-Souligny W, Rola P, Haycock K, Bouchard J, Lamarche Y, Spiegel R, Denault AY"
              },
              "components": [
                {
                  "met": false,
                  "factor": "ivc_dilated"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "hepatic_severe"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "portal_severe"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "renal_severe"
                },
                {
                  "met": true,
                  "factor": "grade_0"
                },
                {
                  "met": false,
                  "factor": "grade_1"
                },
                {
                  "met": false,
                  "factor": "grade_2"
                },
                {
                  "met": false,
                  "factor": "grade_3"
                }
              ],
              "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
              "ivc_dilated": false,
              "vexus_grade": 0,
              "formula_expression": "VExUS C grade 0 if ivc_dilated is false (regardless of Doppler); else 1 if zero of hepatic/portal/renal are severe; 2 if exactly one is severe; 3 if two or more are severe (Beaubien-Souligny 2020 prototype C). Hepatic: normal (triphasic S>D toward liver), mild (S<D toward liver), severe (S reversed toward heart). Portal: mild pulsatility 30 to <50%, severe ≥50%. Renal: mild discontinuous S and D, severe only D. IVC dilated iff maximal diameter ≥2 cm as assigned. Not prototypes A, B, D, E",
              "severe_doppler_count": 0
            },
            {
              "renal": "normal",
              "portal": "normal",
              "formula": "vexus",
              "hepatic": "normal",
              "citation": {
                "id": "beaubien-souligny-2020",
                "doi": "10.1186/s13089-020-00163-w",
                "pmid": "32270297",
                "title": "Quantifying systemic congestion with Point-Of-Care ultrasound: development of the venous excess ultrasound grading system",
                "source": "Ultrasound J. 2020;12(1):16",
                "authors": "Beaubien-Souligny W, Rola P, Haycock K, Bouchard J, Lamarche Y, Spiegel R, Denault AY"
              },
              "components": [
                {
                  "met": false,
                  "factor": "ivc_dilated"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "hepatic_severe"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "portal_severe"
                },
                {
                  "met": false,
                  "value": "normal",
                  "factor": "renal_severe"
                },
                {
                  "met": true,
                  "factor": "grade_0"
                },
                {
                  "met": false,
                  "factor": "grade_1"
                },
                {
                  "met": false,
                  "factor": "grade_2"
                },
                {
                  "met": false,
                  "factor": "grade_3"
                }
              ],
              "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
              "ivc_dilated": false,
              "vexus_grade": 0,
              "formula_expression": "VExUS C grade 0 if ivc_dilated is false (regardless of Doppler); else 1 if zero of hepatic/portal/renal are severe; 2 if exactly one is severe; 3 if two or more are severe (Beaubien-Souligny 2020 prototype C). Hepatic: normal (triphasic S>D toward liver), mild (S<D toward liver), severe (S reversed toward heart). Portal: mild pulsatility 30 to <50%, severe ≥50%. Renal: mild discontinuous S and D, severe only D. IVC dilated iff maximal diameter ≥2 cm as assigned. Not prototypes A, B, D, E",
              "severe_doppler_count": 0
            }
          ]
        }
      },
      "iconUrl": "https://api.magentlab.com/favicon.ico"
    },
    "schema": {
      "type": "object",
      "$schema": "https://json-schema.org/draft/2020-12/schema",
      "required": [
        "input"
      ],
      "properties": {
        "input": {
          "type": "object",
          "required": [
            "type",
            "method"
          ],
          "properties": {
            "body": {
              "type": "object",
              "required": [
                "items"
              ],
              "properties": {
                "items": {
                  "type": "array",
                  "items": {
                    "type": "object",
                    "required": [
                      "ivc_dilated",
                      "hepatic",
                      "portal",
                      "renal"
                    ],
                    "properties": {
                      "renal": {
                        "enum": [
                          "normal",
                          "mild",
                          "severe"
                        ],
                        "type": "string",
                        "description": "Intra-renal venous Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1): normal (continuous flow); mild (discontinuous with a systolic and a diastolic phase); severe (discontinuous with only a diastolic phase during the cardiac cycle). magent does not perform ultrasound."
                      },
                      "portal": {
                        "enum": [
                          "normal",
                          "mild",
                          "severe"
                        ],
                        "type": "string",
                        "description": "Portal-vein Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1 caption): normal (pulsatility fraction not in the mild or severe bands); mild (velocity variation 30 to <50%); severe (variation ≥50%). magent does not perform ultrasound."
                      },
                      "hepatic": {
                        "enum": [
                          "normal",
                          "mild",
                          "severe"
                        ],
                        "type": "string",
                        "description": "Hepatic-vein Doppler grade as assigned by the caller (Beaubien-Souligny 2020 Figure 1): normal (not mild and not severe; triphasic S > D toward the liver); mild (S component lower in magnitude than D but still toward the liver); severe (S component reversed, toward the heart). magent does not perform ultrasound."
                      },
                      "ivc_dilated": {
                        "type": "boolean",
                        "description": "Whether the IVC is dilated as assigned by the caller. Dilated iff maximal IVC diameter ≥2 cm (Beaubien-Souligny 2020). true or false. Grade 0 whenever this is false, regardless of Doppler. magent does not measure IVC."
                      }
                    }
                  },
                  "maxItems": 25,
                  "minItems": 1
                }
              },
              "additionalProperties": false
            },
            "type": {
              "type": "string",
              "const": "http"
            },
            "method": {
              "type": "string",
              "const": "POST"
            },
            "headers": {
              "type": "object",
              "additionalProperties": {
                "type": "string"
              }
            }
          },
          "additionalProperties": false
        },
        "output": {
          "type": "object",
          "required": [
            "type"
          ],
          "properties": {
            "type": {
              "type": "string"
            },
            "example": {
              "type": "object"
            }
          }
        }
      }
    }
  }
}

Provenance

Seen in the source catalog
2026-08-31 12:55Z
Last indexed by Roundhouse
2026-09-07 06:20Z
Last enriched (probe, favicon, geo)
2026-09-22 08:15Z
x402 version
2
Max timeout
600s
Liveness probe
HTTP 402
Report

Hand this page to an agent

Copy the prompt and paste it into Claude, an MCP client or your own agent — it will vet this service and call it over the free read API. No key, no account.

GET api.roundhouseai.io/v0/endpoints

This endpoint's own trailing-30-day call count, as published by the upstream catalog and snapshotted daily. 10 snapshots so far. Verified volume counts only settlements with an on-chain EIP-3009 marker.

Open skill.md
Show the prompt
Using Roundhouse, look up the x402 service magent and tell me whether it is
worth paying: what a call costs, whether the endpoint answered when last probed, and what
its payment record actually shows.

curl -s 'https://api.roundhouseai.io/v0/endpoints?q=magent'
curl -s 'https://api.roundhouseai.io/v0/merchants/<the payTo wallet returned above>'

Then call it: read the price from the live 402 at https://api.magentlab.com/api/calc/vexus, never from
a cached figure, and pay with an x402 client.

The /v0 API needs an API key (`authorization: Bearer rh_live_…`) on everything except
/v0/unified* and /v0/endpoints. Mint a personal key for $0.01 at GET https://api.roundhouseai.io/v0/test/x402,
or use an organization key from https://roundhouseai.io/dashboard/team.

If you do not have Roundhouse tools or skills installed, read
https://roundhouseai.io/skill.md first — it is the whole procedure.