magent
Deterministic published-formula arithmetic plus ICD-10-CM, RxNorm, and LOINC. Pay in USDC on Base via x402.
The wallet the 402 directs payment to. Its whole payment record — every payer, every chain — is on the merchant page.
Asset 0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913
The payTo wallet does not resolve to a registered ERC-8004 agent. That is not a verdict on the service — most of the catalog is unregistered.
Live 402 challenge
Captured by the enrichment pass, not read just now. Prices can change — always read the 402 the endpoint answers with.
{
"error": "PAYMENT-SIGNATURE header is required",
"accepts": [
{
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"extra": {
"name": "USD Coin",
"version": "2",
"paymentFlow": "upfront",
"resourceUrl": "https://api.magentlab.com/api/calc/news2",
"assetTransferMethod": "eip3009"
},
"payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
"amount": "5000",
"scheme": "exact",
"network": "eip155:8453",
"maxTimeoutSeconds": 600
},
{
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"extra": {
"name": "USD Coin",
"version": "2",
"withdrawDelay": 86400,
"receiverAuthorizer": "0x3721824a31197dcDD2984cF43b92B6cc8A87c0Fb",
"assetTransferMethod": "eip3009"
},
"payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
"amount": "5000",
"scheme": "batch-settlement",
"network": "eip155:8453",
"maxTimeoutSeconds": 600
}
],
"resource": {
"url": "https://api.magentlab.com/api/calc/news2",
"tags": [
"news2",
"early-warning",
"emergency",
"acvpu",
"calculator"
],
"mimeType": "application/json",
"description": "NEWS2 from RCP 2017 Chart 1: respiratory rate, SpO2 on caller-assigned Scale 1 or Scale 2, supplemental oxygen, temperature (C), systolic BP, heart rate, and caller-assigned ACVPU (alert 0; confusion, voice, pain, or unresponsive 3 each) summed to 0-20. Returns Chart 2 clinical_risk (low / low-medium / medium / high) and red_score. Not NEWS 2012; not an ICU-admission order.",
"serviceName": "magent"
},
"extensions": {
"bazaar": {
"info": {
"input": {
"type": "http",
"method": "GET",
"queryParams": {
"acvpu": "alert",
"spo2_scale": 1,
"spo2_percent": 98,
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"supplemental_oxygen": false
}
},
"output": {
"type": "json",
"example": {
"acvpu": "alert",
"score": 0,
"formula": "news2",
"citation": {
"id": "rcp-news2-2017",
"title": "National Early Warning Score (NEWS) 2: Standardising the assessment of acute-illness severity in the NHS. Updated report of a working party",
"source": "London: RCP; 2017. ISBN 978-1-86016-682-2",
"authors": "Royal College of Physicians"
},
"max_score": 20,
"red_score": false,
"components": [
{
"value": 16,
"factor": "respiratory_rate",
"points": 0,
"present": false
},
{
"value": 98,
"factor": "spo2_percent",
"points": 0,
"present": false
},
{
"value": false,
"factor": "supplemental_oxygen",
"points": 0,
"present": false
},
{
"value": 37,
"factor": "temperature_c",
"points": 0,
"present": false
},
{
"value": 120,
"factor": "systolic_mm_hg",
"points": 0,
"present": false
},
{
"value": 70,
"factor": "heart_rate_bpm",
"points": 0,
"present": false
},
{
"value": "alert",
"factor": "acvpu",
"points": 0,
"present": false
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"spo2_scale": 1,
"spo2_percent": 98,
"clinical_risk": "low",
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"formula_expression": "NEWS2 = rr_points + spo2_points + oxygen_points + temp_points + sbp_points + hr_points + acvpu_points; RCP NEWS2 2017 Chart 1 (Scale 1 or Scale 2); max 20",
"supplemental_oxygen": false
}
},
"iconUrl": "https://api.magentlab.com/favicon.ico"
},
"schema": {
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"input"
],
"properties": {
"input": {
"type": "object",
"required": [
"type",
"method"
],
"properties": {
"type": {
"type": "string",
"const": "http"
},
"method": {
"enum": [
"GET",
"HEAD",
"DELETE"
],
"type": "string"
},
"headers": {
"type": "object",
"additionalProperties": {
"type": "string"
}
},
"queryParams": {
"type": "object",
"required": [
"systolic_mm_hg",
"heart_rate_bpm",
"respiratory_rate",
"temperature_c",
"spo2_percent",
"spo2_scale",
"supplemental_oxygen",
"acvpu"
],
"properties": {
"acvpu": {
"enum": [
"alert",
"confusion",
"voice",
"pain",
"unresponsive"
],
"type": "string",
"description": "Caller-assigned ACVPU (alert, confusion, voice, pain, or unresponsive). RCP NEWS2 2017 Chart 1: alert → 0; confusion, voice, pain, or unresponsive → 3 each. magent does not compute GCS here."
},
"spo2_scale": {
"enum": [
1,
2
],
"type": "integer",
"description": "Caller-assigned SpO2 scale (1 or 2). Scale 1 is the usual target. Scale 2 is only for a prescribed 88-92% target in confirmed hypercapnic respiratory failure. magent does not choose the scale."
},
"spo2_percent": {
"type": "number",
"description": "Oxygen saturation percent (50-100). Scale 1: ≤91 → 3, 92-93 → 2, 94-95 → 1, ≥96 → 0. Scale 2: ≤83 → 3, 84-85 → 2, 86-87 → 1, 88-92 → 0; ≥93 on air → 0; 93-94 on oxygen → 1, 95-96 on oxygen → 2, ≥97 on oxygen → 3."
},
"temperature_c": {
"type": "number",
"description": "Temperature in °C (30.0-45.0). RCP NEWS2 2017 Chart 1: ≤35.0 → 3, 35.1-36.0 → 1, 36.1-38.0 → 0, 38.1-39.0 → 1, ≥39.1 → 2. magent does not convert Fahrenheit."
},
"heart_rate_bpm": {
"type": "integer",
"description": "Heart rate in beats/min (integer 30-220). RCP NEWS2 2017 Chart 1: ≤40 → 3, 41-50 → 1, 51-90 → 0, 91-110 → 1, 111-130 → 2, ≥131 → 3."
},
"systolic_mm_hg": {
"type": "integer",
"description": "Systolic blood pressure in mm Hg (integer 0-300). RCP NEWS2 2017 Chart 1: ≤90 → 3, 91-100 → 2, 101-110 → 1, 111-219 → 0, ≥220 → 3."
},
"respiratory_rate": {
"type": "integer",
"description": "Respiratory rate in breaths/min (integer 0-80). RCP NEWS2 2017 Chart 1: ≤8 → 3, 9-11 → 1, 12-20 → 0, 21-24 → 2, ≥25 → 3."
},
"supplemental_oxygen": {
"type": "boolean",
"description": "Any supplemental oxygen as assigned by the caller (true or false). RCP NEWS2 2017 Chart 1: true → 2, false → 0. On Scale 2 this also selects air vs oxygen SpO2 bands at ≥93%."
}
}
}
},
"additionalProperties": false
},
"output": {
"type": "object",
"required": [
"type"
],
"properties": {
"type": {
"type": "string"
},
"example": {
"type": "object"
}
}
}
}
}
}
},
"x402Version": 2
}Accepts
The payment requirements as published to the catalog. Read the live 402 before paying — a price here is a claim, not a quote.
Pay 0.005 USDC on Base to 0x836B…19Ee2. The signed payment is good for 10 minutes.
- Paid to
- 0x836B…19Ee2
- USD Coin contract
- 0x8335…02913
- Payment window
- 10 minutes
- As published
- 5000 smallest units
The catalog’s raw entry
[
{
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"extra": {
"name": "USD Coin",
"version": "2",
"paymentFlow": "upfront",
"resourceUrl": "https://api.magentlab.com/api/calc/news2",
"assetTransferMethod": "eip3009"
},
"payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
"amount": "5000",
"scheme": "exact",
"network": "eip155:8453",
"maxTimeoutSeconds": 600
}
]Extensions
{
"bazaar": {
"info": {
"input": {
"body": {
"items": [
{
"acvpu": "alert",
"spo2_scale": 1,
"spo2_percent": 98,
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"supplemental_oxygen": false
},
{
"acvpu": "alert",
"spo2_scale": 1,
"spo2_percent": 98,
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"supplemental_oxygen": false
}
]
},
"type": "http",
"method": "POST"
},
"output": {
"type": "json",
"example": {
"path": "/api/calc/news2",
"count": 2,
"items": [
{
"acvpu": "alert",
"score": 0,
"formula": "news2",
"citation": {
"id": "rcp-news2-2017",
"title": "National Early Warning Score (NEWS) 2: Standardising the assessment of acute-illness severity in the NHS. Updated report of a working party",
"source": "London: RCP; 2017. ISBN 978-1-86016-682-2",
"authors": "Royal College of Physicians"
},
"max_score": 20,
"red_score": false,
"components": [
{
"value": 16,
"factor": "respiratory_rate",
"points": 0,
"present": false
},
{
"value": 98,
"factor": "spo2_percent",
"points": 0,
"present": false
},
{
"value": false,
"factor": "supplemental_oxygen",
"points": 0,
"present": false
},
{
"value": 37,
"factor": "temperature_c",
"points": 0,
"present": false
},
{
"value": 120,
"factor": "systolic_mm_hg",
"points": 0,
"present": false
},
{
"value": 70,
"factor": "heart_rate_bpm",
"points": 0,
"present": false
},
{
"value": "alert",
"factor": "acvpu",
"points": 0,
"present": false
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"spo2_scale": 1,
"spo2_percent": 98,
"clinical_risk": "low",
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"formula_expression": "NEWS2 = rr_points + spo2_points + oxygen_points + temp_points + sbp_points + hr_points + acvpu_points; RCP NEWS2 2017 Chart 1 (Scale 1 or Scale 2); max 20",
"supplemental_oxygen": false
},
{
"acvpu": "alert",
"score": 0,
"formula": "news2",
"citation": {
"id": "rcp-news2-2017",
"title": "National Early Warning Score (NEWS) 2: Standardising the assessment of acute-illness severity in the NHS. Updated report of a working party",
"source": "London: RCP; 2017. ISBN 978-1-86016-682-2",
"authors": "Royal College of Physicians"
},
"max_score": 20,
"red_score": false,
"components": [
{
"value": 16,
"factor": "respiratory_rate",
"points": 0,
"present": false
},
{
"value": 98,
"factor": "spo2_percent",
"points": 0,
"present": false
},
{
"value": false,
"factor": "supplemental_oxygen",
"points": 0,
"present": false
},
{
"value": 37,
"factor": "temperature_c",
"points": 0,
"present": false
},
{
"value": 120,
"factor": "systolic_mm_hg",
"points": 0,
"present": false
},
{
"value": 70,
"factor": "heart_rate_bpm",
"points": 0,
"present": false
},
{
"value": "alert",
"factor": "acvpu",
"points": 0,
"present": false
}
],
"disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
"spo2_scale": 1,
"spo2_percent": 98,
"clinical_risk": "low",
"temperature_c": 37,
"heart_rate_bpm": 70,
"systolic_mm_hg": 120,
"respiratory_rate": 16,
"formula_expression": "NEWS2 = rr_points + spo2_points + oxygen_points + temp_points + sbp_points + hr_points + acvpu_points; RCP NEWS2 2017 Chart 1 (Scale 1 or Scale 2); max 20",
"supplemental_oxygen": false
}
]
}
},
"iconUrl": "https://api.magentlab.com/favicon.ico"
},
"schema": {
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"input"
],
"properties": {
"input": {
"type": "object",
"required": [
"type",
"method"
],
"properties": {
"body": {
"type": "object",
"required": [
"items"
],
"properties": {
"items": {
"type": "array",
"items": {
"type": "object",
"required": [
"systolic_mm_hg",
"heart_rate_bpm",
"respiratory_rate",
"temperature_c",
"spo2_percent",
"spo2_scale",
"supplemental_oxygen",
"acvpu"
],
"properties": {
"acvpu": {
"enum": [
"alert",
"confusion",
"voice",
"pain",
"unresponsive"
],
"type": "string",
"description": "Caller-assigned ACVPU (alert, confusion, voice, pain, or unresponsive). RCP NEWS2 2017 Chart 1: alert → 0; confusion, voice, pain, or unresponsive → 3 each. magent does not compute GCS here."
},
"spo2_scale": {
"enum": [
1,
2
],
"type": "integer",
"description": "Caller-assigned SpO2 scale (1 or 2). Scale 1 is the usual target. Scale 2 is only for a prescribed 88-92% target in confirmed hypercapnic respiratory failure. magent does not choose the scale."
},
"spo2_percent": {
"type": "number",
"description": "Oxygen saturation percent (50-100). Scale 1: ≤91 → 3, 92-93 → 2, 94-95 → 1, ≥96 → 0. Scale 2: ≤83 → 3, 84-85 → 2, 86-87 → 1, 88-92 → 0; ≥93 on air → 0; 93-94 on oxygen → 1, 95-96 on oxygen → 2, ≥97 on oxygen → 3."
},
"temperature_c": {
"type": "number",
"description": "Temperature in °C (30.0-45.0). RCP NEWS2 2017 Chart 1: ≤35.0 → 3, 35.1-36.0 → 1, 36.1-38.0 → 0, 38.1-39.0 → 1, ≥39.1 → 2. magent does not convert Fahrenheit."
},
"heart_rate_bpm": {
"type": "integer",
"description": "Heart rate in beats/min (integer 30-220). RCP NEWS2 2017 Chart 1: ≤40 → 3, 41-50 → 1, 51-90 → 0, 91-110 → 1, 111-130 → 2, ≥131 → 3."
},
"systolic_mm_hg": {
"type": "integer",
"description": "Systolic blood pressure in mm Hg (integer 0-300). RCP NEWS2 2017 Chart 1: ≤90 → 3, 91-100 → 2, 101-110 → 1, 111-219 → 0, ≥220 → 3."
},
"respiratory_rate": {
"type": "integer",
"description": "Respiratory rate in breaths/min (integer 0-80). RCP NEWS2 2017 Chart 1: ≤8 → 3, 9-11 → 1, 12-20 → 0, 21-24 → 2, ≥25 → 3."
},
"supplemental_oxygen": {
"type": "boolean",
"description": "Any supplemental oxygen as assigned by the caller (true or false). RCP NEWS2 2017 Chart 1: true → 2, false → 0. On Scale 2 this also selects air vs oxygen SpO2 bands at ≥93%."
}
}
},
"maxItems": 25,
"minItems": 1
}
},
"additionalProperties": false
},
"type": {
"type": "string",
"const": "http"
},
"method": {
"type": "string",
"const": "POST"
},
"headers": {
"type": "object",
"additionalProperties": {
"type": "string"
}
}
},
"additionalProperties": false
},
"output": {
"type": "object",
"required": [
"type"
],
"properties": {
"type": {
"type": "string"
},
"example": {
"type": "object"
}
}
}
}
}
}
}Provenance
- Seen in the source catalog
- 2026-08-31 13:28Z
- Last indexed by Roundhouse
- 2026-09-07 06:20Z
- Last enriched (probe, favicon, geo)
- 2026-09-12 11:15Z
- x402 version
- 2
- Max timeout
- 600s
- Liveness probe
- HTTP 0
Hand this page to an agent
Copy the prompt and paste it into Claude, an MCP client or your own agent — it will vet this service and call it over the free read API. No key, no account.
GET api.roundhouseai.io/v0/endpoints
This endpoint's own trailing-30-day call count, as published by the upstream catalog and snapshotted daily. 14 snapshots so far. Verified volume counts only settlements with an on-chain EIP-3009 marker.
Show the promptHide the prompt
Using Roundhouse, look up the x402 service magent and tell me whether it is worth paying: what a call costs, whether the endpoint answered when last probed, and what its payment record actually shows. curl -s 'https://api.roundhouseai.io/v0/endpoints?q=magent' curl -s 'https://api.roundhouseai.io/v0/merchants/<the payTo wallet returned above>' Then call it: read the price from the live 402 at https://api.magentlab.com/api/calc/news2, never from a cached figure, and pay with an x402 client. The /v0 API needs an API key (`authorization: Bearer rh_live_…`) on everything except /v0/unified* and /v0/endpoints. Mint a personal key for $0.01 at GET https://api.roundhouseai.io/v0/test/x402, or use an organization key from https://roundhouseai.io/dashboard/team. If you do not have Roundhouse tools or skills installed, read https://roundhouseai.io/skill.md first — it is the whole procedure.