Electronics Calculators
AWG copper wire: diameter, area and resistance per km, the nearest AWG for an area, and voltage drop over a run.
The wallet the 402 directs payment to. Its whole payment record — every payer, every chain — is on the merchant page.
Asset 0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913
The payTo wallet does not resolve to a registered ERC-8004 agent. That is not a verdict on the service — most of the catalog is unregistered.
Live 402 challenge
Captured by the enrichment pass, not read just now. Prices can change — always read the 402 the endpoint answers with.
{
"error": "Payment required",
"accepts": [
{
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"extra": {
"name": "USD Coin",
"version": "2"
},
"payTo": "0xb531320805C5BED1D46AEaDcF4F008FDF172DBDa",
"scheme": "exact",
"network": "base",
"mimeType": "application/json",
"resource": "https://electronics-calc.x402tookit.com/wire-gauge",
"description": "AWG copper wire: diameter, area and resistance per km, the nearest AWG for an area, and voltage drop over a run.",
"outputSchema": {
"input": {
"type": "http",
"method": "GET",
"queryParams": {
"awg": 18,
"lengthM": 10,
"supplyV": 12,
"currentA": 2
}
},
"output": {
"awg": 18,
"asOf": "2026-10-11T08:33:13.563Z",
"note": null,
"basis": "solid annealed copper at 20 C (1.7241e-8 ohm metre)",
"source": "computed locally",
"areaMm2": 0.82305,
"reasons": [
"Diameter = 0.127 mm x 92^((36 - n) / 39). Lower AWG numbers are thicker wire.",
"Voltage drop uses the round-trip length (there and back). A common design target is under 3% drop.",
"…1 more"
],
"summary": "AWG 18: 1.024 mm (0.0403 in), 0.823 mm2, 20.95 ohm/km. 10 m out and back at 2 A drops 0.8379 V (6.98% of 12 V), wasting 1.68 W.",
"verdict": "COMPUTED",
"degraded": false,
"diameterMm": 1.0237,
"disclaimer": "Screening signal computed from the named public source. Not financial, legal or investment advice; provided as is. Verify at the source before acting.",
"notChecked": [
"AMPACITY: this service does NOT say how much current a wire can safely carry. That depends on insulation, bundling, ambient temperature, and local electrical codes: use the code tables or a qualified …",
"aluminium or other conductors (copper only)",
"…2 more"
],
"powerLossW": 1.67582,
"loopLengthM": 20,
"diameterInch": 0.040303,
"voltageDropV": 0.837911,
"voltageDropPct": 6.983,
"loopResistanceOhm": 0.418956,
"copperResistanceOhmPerKm": 20.948,
"copperResistanceOhmPer1000ft": 6.3849
}
},
"maxAmountRequired": "20000",
"maxTimeoutSeconds": 300
},
{
"asset": "EPjFWdd5AufqSSqeM2qN1xzybapC8G4wEGGkZwyTDt1v",
"extra": {
"feePayer": "BFK9TLC3edb13K6v4YyH3DwPb5DSUpkWvb7XnqCL9b4F"
},
"payTo": "DUPiupXtuox38dcGoXUKer5mAydCzmaHjrbQ66qeEm8s",
"scheme": "exact",
"network": "solana",
"mimeType": "application/json",
"resource": "https://electronics-calc.x402tookit.com/wire-gauge",
"description": "AWG copper wire: diameter, area and resistance per km, the nearest AWG for an area, and voltage drop over a run.",
"outputSchema": {
"input": {
"type": "http",
"method": "GET",
"queryParams": {
"awg": 18,
"lengthM": 10,
"supplyV": 12,
"currentA": 2
}
},
"output": {
"awg": 18,
"asOf": "2026-10-11T08:33:13.563Z",
"note": null,
"basis": "solid annealed copper at 20 C (1.7241e-8 ohm metre)",
"source": "computed locally",
"areaMm2": 0.82305,
"reasons": [
"Diameter = 0.127 mm x 92^((36 - n) / 39). Lower AWG numbers are thicker wire.",
"Voltage drop uses the round-trip length (there and back). A common design target is under 3% drop.",
"…1 more"
],
"summary": "AWG 18: 1.024 mm (0.0403 in), 0.823 mm2, 20.95 ohm/km. 10 m out and back at 2 A drops 0.8379 V (6.98% of 12 V), wasting 1.68 W.",
"verdict": "COMPUTED",
"degraded": false,
"diameterMm": 1.0237,
"disclaimer": "Screening signal computed from the named public source. Not financial, legal or investment advice; provided as is. Verify at the source before acting.",
"notChecked": [
"AMPACITY: this service does NOT say how much current a wire can safely carry. That depends on insulation, bundling, ambient temperature, and local electrical codes: use the code tables or a qualified …",
"aluminium or other conductors (copper only)",
"…2 more"
],
"powerLossW": 1.67582,
"loopLengthM": 20,
"diameterInch": 0.040303,
"voltageDropV": 0.837911,
"voltageDropPct": 6.983,
"loopResistanceOhm": 0.418956,
"copperResistanceOhmPerKm": 20.948,
"copperResistanceOhmPer1000ft": 6.3849
}
},
"maxAmountRequired": "20000",
"maxTimeoutSeconds": 300
},
{
"asset": "0x3c499c542cEF5E3811e1192ce70d8cC03d5c3359",
"extra": {
"name": "USD Coin",
"version": "2"
},
"payTo": "0xb531320805C5BED1D46AEaDcF4F008FDF172DBDa",
"scheme": "exact",
"network": "polygon",
"mimeType": "application/json",
"resource": "https://electronics-calc.x402tookit.com/wire-gauge",
"description": "AWG copper wire: diameter, area and resistance per km, the nearest AWG for an area, and voltage drop over a run.",
"outputSchema": {
"input": {
"type": "http",
"method": "GET",
"queryParams": {
"awg": 18,
"lengthM": 10,
"supplyV": 12,
"currentA": 2
}
},
"output": {
"awg": 18,
"asOf": "2026-10-11T08:33:13.563Z",
"note": null,
"basis": "solid annealed copper at 20 C (1.7241e-8 ohm metre)",
"source": "computed locally",
"areaMm2": 0.82305,
"reasons": [
"Diameter = 0.127 mm x 92^((36 - n) / 39). Lower AWG numbers are thicker wire.",
"Voltage drop uses the round-trip length (there and back). A common design target is under 3% drop.",
"…1 more"
],
"summary": "AWG 18: 1.024 mm (0.0403 in), 0.823 mm2, 20.95 ohm/km. 10 m out and back at 2 A drops 0.8379 V (6.98% of 12 V), wasting 1.68 W.",
"verdict": "COMPUTED",
"degraded": false,
"diameterMm": 1.0237,
"disclaimer": "Screening signal computed from the named public source. Not financial, legal or investment advice; provided as is. Verify at the source before acting.",
"notChecked": [
"AMPACITY: this service does NOT say how much current a wire can safely carry. That depends on insulation, bundling, ambient temperature, and local electrical codes: use the code tables or a qualified …",
"aluminium or other conductors (copper only)",
"…2 more"
],
"powerLossW": 1.67582,
"loopLengthM": 20,
"diameterInch": 0.040303,
"voltageDropV": 0.837911,
"voltageDropPct": 6.983,
"loopResistanceOhm": 0.418956,
"copperResistanceOhmPerKm": 20.948,
"copperResistanceOhmPer1000ft": 6.3849
}
},
"maxAmountRequired": "20000",
"maxTimeoutSeconds": 300
}
],
"x402Version": 1,
"alsoAvailable": {
"llms": "https://electronics-calc.x402tookit.com/llms.txt",
"catalog": "https://electronics-calc.x402tookit.com/catalog",
"message": "Electronics Calculators has 11 pay-per-call endpoints (Ohm's law, resistor codes and standard values, dividers, LED resistors, RC filters, battery runtime, wire gauge, decibels, 555 timers, power cost.), from $0.02 a call. See the full menu and send your agents our way.",
"openapi": "https://electronics-calc.x402tookit.com/openapi.json",
"related": [
{
"url": "https://electronics-calc.x402tookit.com/battery-runtime",
"path": "/battery-runtime",
"what": "Battery runtime estimate from capacity (mAh and volts, or Wh) and load (mA or W), with ef…",
"price": "$0.02"
},
{
"url": "https://electronics-calc.x402tookit.com/decibels",
"path": "/decibels",
"what": "Decibel conversions: power or voltage ratio to dB and back, and dBm to milliwatts and wat…",
"price": "$0.02"
},
{
"url": "https://electronics-calc.x402tookit.com/led-resistor",
"path": "/led-resistor",
"what": "Series resistor for an LED from supply voltage, forward voltage and current, with nearest…",
"price": "$0.02"
}
]
}
}Accepts
The payment requirements as published to the catalog. Read the live 402 before paying — a price here is a claim, not a quote.
Pay 0.02 USDC on Base to 0xb531…2DBDa. The signed payment is good for 5 minutes.
- Paid to
- 0xb531…2DBDa
- USD Coin contract
- 0x8335…02913
- Payment window
- 5 minutes
- As published
- 20000 smallest units
That figure is in the token’s smallest units. Roundhouse does not hold this contract’s decimals, so it is shown as published rather than converted.
- Paid to
- DUPiup…eEm8s
- Token contract
- EPjFWd…TDt1v
- Payment window
- 5 minutes
That figure is in the token’s smallest units. Roundhouse does not hold this contract’s decimals, so it is shown as published rather than converted.
- Paid to
- 0xb531…2DBDa
- Token contract
- 0x3c49…c3359
- Payment window
- 5 minutes
That figure is in the token’s smallest units. Roundhouse does not hold this contract’s decimals, so it is shown as published rather than converted.
- Paid to
- 0xb531…2DBDa
- Token contract
- 0xaf88…e5831
- Payment window
- 5 minutes
The catalog’s raw entry
[
{
"asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
"extra": {
"name": "USD Coin",
"version": "2"
},
"payTo": "0xb531320805C5BED1D46AEaDcF4F008FDF172DBDa",
"amount": "20000",
"scheme": "exact",
"network": "eip155:8453",
"maxTimeoutSeconds": 300
},
{
"asset": "EPjFWdd5AufqSSqeM2qN1xzybapC8G4wEGGkZwyTDt1v",
"extra": {
"feePayer": "D6ZhtNQ5nT9ZnTHUbqXZsTx5MH2rPFiBBggX4hY1WePM"
},
"payTo": "DUPiupXtuox38dcGoXUKer5mAydCzmaHjrbQ66qeEm8s",
"amount": "20000",
"scheme": "exact",
"network": "solana:5eykt4UsFv8P8NJdTREpY1vzqKqZKvdp",
"maxTimeoutSeconds": 300
},
{
"asset": "0x3c499c542cEF5E3811e1192ce70d8cC03d5c3359",
"extra": {
"name": "USD Coin",
"version": "2"
},
"payTo": "0xb531320805C5BED1D46AEaDcF4F008FDF172DBDa",
"amount": "20000",
"scheme": "exact",
"network": "eip155:137",
"maxTimeoutSeconds": 300
},
{
"asset": "0xaf88d065e77c8cC2239327C5EDb3A432268e5831",
"extra": {
"name": "USD Coin",
"version": "2"
},
"payTo": "0xb531320805C5BED1D46AEaDcF4F008FDF172DBDa",
"amount": "20000",
"scheme": "exact",
"network": "eip155:42161",
"maxTimeoutSeconds": 300
}
]Extensions
{
"bazaar": {
"info": {
"input": {
"type": "http",
"method": "GET",
"queryParams": {
"awg": 18,
"lengthM": 10,
"supplyV": 12,
"currentA": 2
}
},
"output": {
"type": "json",
"example": {
"awg": 18,
"asOf": "2026-10-11T08:33:13.563Z",
"note": null,
"basis": "solid annealed copper at 20 C (1.7241e-8 ohm metre)",
"source": "computed locally",
"areaMm2": 0.82305,
"reasons": [
"Diameter = 0.127 mm x 92^((36 - n) / 39). Lower AWG numbers are thicker wire.",
"Voltage drop uses the round-trip length (there and back). A common design target is under 3% drop.",
"…1 more"
],
"summary": "AWG 18: 1.024 mm (0.0403 in), 0.823 mm2, 20.95 ohm/km. 10 m out and back at 2 A drops 0.8379 V (6.98% of 12 V), wasting 1.68 W.",
"verdict": "COMPUTED",
"degraded": false,
"diameterMm": 1.0237,
"disclaimer": "Screening signal computed from the named public source. Not financial, legal or investment advice; provided as is. Verify at the source before acting.",
"notChecked": [
"AMPACITY: this service does NOT say how much current a wire can safely carry. That depends on insulation, bundling, ambient temperature, and local electrical codes: use the code tables or a qualified …",
"aluminium or other conductors (copper only)",
"…2 more"
],
"powerLossW": 1.67582,
"loopLengthM": 20,
"diameterInch": 0.040303,
"voltageDropV": 0.837911,
"voltageDropPct": 6.983,
"loopResistanceOhm": 0.418956,
"copperResistanceOhmPerKm": 20.948,
"copperResistanceOhmPer1000ft": 6.3849
}
}
},
"schema": {
"type": "object",
"$schema": "https://json-schema.org/draft/2020-12/schema",
"required": [
"input"
],
"properties": {
"input": {
"type": "object",
"required": [
"type",
"method"
],
"properties": {
"type": {
"type": "string",
"const": "http"
},
"method": {
"enum": [
"GET"
],
"type": "string"
},
"queryParams": {
"type": "object",
"required": [],
"properties": {
"awg": {
"type": "integer",
"description": "AWG number, -3 to 40 (use instead of areaMm2)"
},
"areaMm2": {
"type": "number",
"description": "Cross-section in mm2 to find the nearest AWG"
},
"lengthM": {
"type": "number",
"description": "One-way run length in metres for voltage drop"
},
"supplyV": {
"type": "number",
"description": "Supply volts to express the drop as a percentage"
},
"currentA": {
"type": "number",
"description": "Current in amps for voltage drop"
}
}
}
},
"additionalProperties": false
},
"output": {
"type": "object",
"required": [
"type"
],
"properties": {
"type": {
"type": "string"
},
"example": {
"type": "object",
"properties": {
"awg": {
"type": [
"null",
"number"
]
},
"asOf": {
"type": [
"null",
"string"
]
},
"note": {},
"basis": {
"type": [
"null",
"string"
]
},
"source": {
"type": [
"null",
"string"
]
},
"areaMm2": {
"type": [
"null",
"number"
]
},
"reasons": {
"type": [
"array",
"null"
],
"items": {
"type": "string"
}
},
"summary": {
"type": [
"null",
"string"
]
},
"verdict": {
"type": [
"null",
"string"
]
},
"degraded": {
"type": [
"boolean",
"null"
]
},
"diameterMm": {
"type": [
"null",
"number"
]
},
"disclaimer": {
"type": [
"null",
"string"
]
},
"notChecked": {
"type": [
"array",
"null"
],
"items": {
"type": "string"
}
},
"powerLossW": {
"type": [
"null",
"number"
]
},
"loopLengthM": {
"type": [
"null",
"number"
]
},
"diameterInch": {
"type": [
"null",
"number"
]
},
"voltageDropV": {
"type": [
"null",
"number"
]
},
"voltageDropPct": {
"type": [
"null",
"number"
]
},
"loopResistanceOhm": {
"type": [
"null",
"number"
]
},
"copperResistanceOhmPerKm": {
"type": [
"null",
"number"
]
},
"copperResistanceOhmPer1000ft": {
"type": [
"null",
"number"
]
}
}
}
}
}
}
}
}
}Provenance
- Seen in the source catalog
- 2026-10-20 20:48Z
- Last indexed by Roundhouse
- 2026-10-22 12:40Z
- Last enriched (probe, favicon, geo)
- 2026-10-20 23:45Z
- x402 version
- 2
- Max timeout
- 300s
- Liveness probe
- HTTP 402
Hand this page to an agent
Copy the prompt and paste it into Claude, an MCP client or your own agent — it will vet this service and call it over the free read API. No key, no account.
GET api.roundhouseai.io/v0/endpoints
This endpoint's own trailing-30-day call count, as published by the upstream catalog and snapshotted daily. 4 snapshots so far. Verified volume counts only settlements with an on-chain EIP-3009 marker.
Show the promptHide the prompt
Using Roundhouse, look up the x402 service Electronics Calculators and tell me whether it is worth paying: what a call costs, whether the endpoint answered when last probed, and what its payment record actually shows. curl -s 'https://api.roundhouseai.io/v0/endpoints?q=Electronics%20Calculators' curl -s 'https://api.roundhouseai.io/v0/merchants/<the payTo wallet returned above>' Then call it: read the price from the live 402 at https://electronics-calc.x402tookit.com/wire-gauge, never from a cached figure, and pay with an x402 client. The /v0 API needs an API key (`authorization: Bearer rh_live_…`) on everything except /v0/unified* and /v0/endpoints. Either pay over x402 (mint a personal key for $0.01 at GET https://api.roundhouseai.io/v0/test/x402), or ask me for an organization key, which I create at https://roundhouseai.io/dashboard/connections. If you have neither, ask before going further. If you do not have Roundhouse tools or skills installed, read https://roundhouseai.io/skill.md first — it is the whole procedure.